Blocks, Interlock & Curbstones Testing
MODONSASO

Blocks, Interlock & Curbstones Testing in Qassim

Compressive strength, water absorption, and dimensional testing for concrete blocks, interlock, and curbstones per ASTM C880 and C99 to verify paving material compliance.

Testing of concrete blocks, interlock pavers, and curbstones consists of laboratory checks verifying compressive strength, water absorption, and dimensions of precast building and paving materials. Performed by an accredited lab per ASTM C140, C880 and SASO specifications, it ensures cement blocks, interlock and curbstones comply with required standards before use in construction and paving projects.

What Is Block and Interlock Testing and Why Is It Required Before Supply?

Testing of blocks, interlock, and curbstones consists of laboratory checks performed on samples from each supply batch to verify compliance with the standard specification. It includes compressive strength to determine load capacity, water absorption reflecting material porosity, and dimensional checks ensuring manufacturing precision and uniform installation.

Cement blocks and interlock pavers are subjected to direct loads and continuous weathering — weak strength or high absorption accelerates cracking and deterioration within a few years of installation. Upfront testing of each supply batch protects the project from having to replace entire paving or wall areas later.

As a laboratory accredited to ISO/IEC 17025:2017 (SAAC accreditation No. N-T-00645) and approved by MODON, Asas Lab performs block, interlock and curbstone testing for factory suppliers and contractors in Makkah, Jeddah, Madinah, Riyadh, and Qassim, issuing certified compliance reports accepted by municipalities and developers.

SASO compliance for paving materials

Preventing installation of low-strength materials

Extending pavement and wall lifespan

Compliance certificates accepted by municipalities

Full List of Certified Tests

6 certified tests per international standards

Compressive Strength

مقاومة إجهاد الكسر

ASTM C140

Measures the maximum load a block or interlock paver withstands before fracture — the core test verifying compliance with SASO requirements for structural or paving use.

Unit: sample

Water Absorption

نسبة الامتصاص

ASTM C140

Measures water absorption inside the block or curbstone — high absorption indicates high porosity, weakening weathering and freeze-thaw resistance.

Unit: sample

Dimensions

الأبعاد

Verifies block or interlock dimensions match the standard specification — essential for accurate installation and uniform load distribution between units.

Unit: sample

Fire Resistance (blocks)

مقاومة الحريق (بلوك)

Evaluates cement block resistance to fire and high heat — required in buildings where the safety code mandates a specific fire-rating for walls.

Unit: sample

Flexural Strength (interlock)

نسبة الانحناء (إنترلوك)

ASTM C880

Measures interlock paver flexural strength under traffic loads — a key durability indicator for car parks and walkways under continuous use.

Unit: sample

Modulus of Rupture (interlock)

معامل التمزق (إنترلوك)

ASTM C99

Determines the interlock modulus of rupture, measuring resistance to fracture under bending — complements the flexural test in assessing paving unit durability.

Unit: test

Blocks and Interlock Testing in Qassim — Building Materials for Residential and Industrial Projects

Qassim's rapid urban expansion across Buraidah, Unayzah, Ar Rass, and surrounding cities consumes large volumes of concrete masonry units. ASAS Lab tests per SASO GSO 68: compressive strength (≥ 7.5 MPa load-bearing), water absorption (≤ 10% structural), and dimensional tolerance (≤ 3 mm). Industrial and commercial interlock pavers are additionally tested for wear resistance and heavy truck load capacity targeting a 25-year service life in Qassim's dry climate. Compliance certificates for building permit files issued within 7 working days.

Adopted Engineering Standards

All block and interlock tests are performed to adopted Saudi and international standards

ASTM C140

The American standard for concrete masonry unit testing

ASTM C880/C99

The American standard for interlock and curbstone testing

SASO

Saudi Standards, Metrology and Quality Organization

ISO 17025

International laboratory accreditation for competence and accuracy

How Does the Block and Interlock Testing Process Work?

From sample receipt to the compliance certificate

1

Contact and Product Type Definition

We receive your request and define the product type — blocks, interlock, or curbstones — and required tests based on use. We send the quotation within 24 hours.

2

Batch Sample Receipt

Our team receives representative samples from the supply batch per the required standard count, documenting the factory and batch for accurate traceability.

3

Laboratory Testing

Samples are tested in our accredited laboratories per ISO 17025 to measure compressive strength, water absorption, dimensions, and compliance with the standard specification.

4

Compliance Certificate Delivery

You receive an engineering-certified compliance certificate showing each sample's results — ready for submission to the municipality, consultant, or developer.

Why Choose Us

Why ASAS Lab?

ISO
International Accreditation

Approved by MODON, ACI, NRRC & KIDANA

15+
Years Experience

Over 500 completed projects across KSA

5
Branches

Makkah, Jeddah, Madinah, Riyadh, Qassim

Precast paving and building materials look similar on the surface — laboratory testing is the only true measure of actual quality

Certified compliance reports accepted by municipalities and developers

Compression presses and testing equipment calibrated periodically per ISO 17025

5 branches in Makkah, Jeddah, Madinah, Riyadh and Qassim

Accepting batches from multiple factories with independent reports

A specialized engineering team to interpret strength and absorption results

15+ years and 500+ projects in building and paving works

What Does the Block and Interlock Test Report Include?

The block and interlock report is the reference the developer or municipality relies on to accept a supply batch

Compressive strength in MPa

Water absorption percentage by weight

Actual dimensions compared to specification

Flexural strength or modulus of rupture for interlock

Comparison of results against adopted SASO specifications

Supply batch acceptance or rejection recommendation

Common Questions

FAQ About Blocks, Interlock & Curbstones Testing

SASO 1006 requires minimum compressive strength of 7 MPa for load-bearing blocks and 4 MPa for non-load-bearing. Interlock pavers must achieve minimum 35 MPa per ASTM C936.

Asas Lab Branch in Qassim

Our field team operates from our بريدة branch, covering all districts of Qassim and nearby areas with calibrated, certified equipment — reports are certified and accepted by government authorities.

Blocks, Interlock & Curbstones Testing Across Saudi Cities

Has a New Block or Interlock Batch Arrived?

Our engineering team is ready to receive samples, with an accurate quotation within 24 hours — block and interlock testing available in 5 cities across the Kingdom

Makkah — Jeddah — Madinah — Riyadh — Qassim